Authorised Australian Distributor — LS Electric

Circuit protection, stocked and supported in Australia.

Protect and control every circuit from final sub-circuit to main switchboard — the full LS Electric stack (Susol MCCBs, Metasol ACBs and contactors, BKN-b MCBs), held in Australian stock by TROPAC with coordination data and PAC support for every selection.
1A–6300AF Protection range (MCB–ACB)
Up to 200kA Breaking capacity
6A–2650A Contactor range
100% Ics = Icu (220–525V)
Australian stock QLD · NSW · VIC warehouses
Ics = Icu on most frames Service breaking = ultimate. No derating surprises.
Coordination data Type 2 MCCB + contactor tables on request
PAC support Fault-level checks & panel schedules
Product range

Circuit protection — MCB to ACB.

The full LS Electric protection stack — BKN-b MCBs for final sub-circuits, Susol MCCBs for sub-mains and distribution, Metasol ACBs for main bus and tie-breakers, MC contactors and MMS starters for motor circuits.

MCB
Miniature Circuit Breakers

For final-circuit protection in the panel — 1–125A in B/C/D curves, AC and DC variants. The panel-builder workhorse.

Range
1 – 125A (BKN-b · BKJ63N · BKH)
Poles
1P – 4P
Breaking
10kA @ 415V AC · 6kA @ 125V DC
Cert
IEC 60898-1 · IEC 60947-2
MC + TOR
Metasol Contactors & TOR

For switching and protecting motor loads — 6A to 2650A, Type 2 coordinated. One of the widest contactor families on the market.

Range
6A – 2650A (MC) · 0.1 – 800A (MT TOR)
Poles
3P / 4P
Coord
Type 2 tables with Susol & Metasol
Cert
IEC 60947-4
ACB
Metasol ACB

For main-incomer and bus-tie duty to 6300AF — marine class on AS-F / AS-G.

Frame
630AF – 6300AF (AN-D · AS-D/E/F/G)
Poles
3P / 4P · draw-out or fixed
Breaking
65 – 120kA @ 415V
Cert
KS · KEMA · marine class (LR / ABS / DNV)
MMS
Manual Motor Starters

For DOL motor protection in one device — overload, short circuit and phase failure to 100A.

Range
0.1 – 100A (MMS-32D · 32S/H · 63H · 100H)
Trip
Overload · short circuit · phase fail (H)
Ops
100,000 mechanical
Cert
IEC 60947-2 + 60947-4
RCBO / RCCB
Residual Current Protection

For earth-leakage protection on AS/NZS 3000 sub-circuits — 10kA RCBOs and RCCBs.

Range
6 – 100A (RKS · RKS-b RCBO · RKN-b RCCB)
Poles
1P+N – 4P
Breaking
10kA · 30/100mA sensitivity
Cert
IEC 61009 · RCM
About LS Electric

Performance Certainty — an engineering standard, not a marketing claim.

LS Electric (formerly LS Industrial Systems) is one of Korea's largest electrical manufacturers with over 70 years of production history. Their Cheongju and Gumi factories build products to IEC standards that are certified by KEMA, CB, and marine classification bodies — third-party tested, not self-certified.

TROPAC has stocked LS Electric since the brand's introduction into the Australian market. When you need coordination data, trip-unit selection advice, or a direct line to the LS Electric technical team, our PACs handle it.

70+yrs
LS Electric manufacturing history
200kA
Max Susol breaking capacity
6300A
Largest Metasol ACB frame
3
TROPAC stocking locations(Australia-wide)
Ready to specify

Build your panel around protection you can prove.

LS Electric gives you data sheets, coordination tables and third-party certificates — not just a catalogue page. TROPAC holds stock and puts a PAC in front of you when the coordination gets complicated.

Talk to a specialist

Need help specifying?

Send the team your application and a TROPAC Product Application Consultant will come back with the right LS Electric product, stock position and account pricing — usually same business day.

  • Selection & cross-reference from your current part numbers
  • Live stock check across QLD, NSW & VIC
  • Trade-account & project pricing
Enquiry · LS Electric
No obligation · usually same business day