Authorised Australian Distributor — icotek

Cable entry, sealed and strain-relieved in one frame.

Route, seal and strain-relieve every cable — with or without connectors — through a single panel cut-out. icotek split entry frames, grommets, membrane plates, glands, brush seals and hygienic/EMC entries, up to IP66 / UL Type 4X. Stocked in Australia through TROPAC.
IP54–IP66 Ingress range
1–75mm Cable diameter
EN 62444 Integrated strain relief
UL Type 4X select models
Australian stock QLD · NSW · VIC warehouses
Route & seal Frames, grommets, glands & plates
Strain relief built in Certified to EN 62444
PAC support Grommet sizing & cut-out specs
Find your solution

What are you routing?

Start with the cable — we'll point you to the right frame, grommet or gland.

Application
Route many pre-terminated cables through one cut-out
Split KEL frames take KT grommets sized to each cable, so connectorised and unterminated cables route and seal through a single cut-out. Match 10-, 16- and 24-pin industrial connector cut-outs.
Split Cable Entry Frames (KEL)
View range
Application
Quick, sealed entry for individual cables
Membrane cable entry plates seal individual cables 1.5–22 mm as they pass through — snap-in or screw-in, no grommets needed. Versatile, secure and fast to install.
Membrane Entry Plates
View Range
Application
Route unterminated cables and reduce particle entry
Brush-seal cable entries route large bundles of non-terminated cables while a dense brush reduces dust and particle ingress. Screw or snap fitments to suit the panel.
Brush-Seal Cable Entry
View Range
Application
Seal a single pre-terminated cable at a gland point
KVT split cable glands guide and re-route pre-terminated cables through a standard gland thread without cutting the connector off — screw mount, fast retrofit.
Split Cable Glands (KVT)
VIEW RANGE
Application
Washdown, cleanroom or food/pharma routing
FDA-compliant hygienic cable entries with smooth, visible surfaces and no dirt traps — for food, beverage and pharma environments that have to pass a washdown spec.
Hygienic Entries
View Range
Application
EMC shielding or dedicated strain relief
EMC cable collectors with EMI shielding plus strain-relief entries certified to EN 62444 — manage shielding and hold cables securely on the same entry.
Strain Relief & EMC
View range
Not sure?
I need help choosing a cable entry solution
Our PACs can advise on grommet sizing, frame selection, cut-out dimensions, IP rating, strain relief and EMC requirements — from a single entry to a full panel cable schedule.
Free selection support
Contact a PAC
Product range

The icotek range.

Cable management for control panels, enclosures and machines, stocked in Australia. Split entry frames, grommets, membrane plates, glands and hygienic entries — routing, sealing and strain relief in one system, up to IP66 / UL Type 4X.

KEL series
Split Cable Entry Frames

For routing many cables — with or without connectors — through one panel cut-out. Centrally split KEL frames take KT grommets sized to each cable, sealing and strain-relieving in a single frame. The default starting point for most panel builds.

KEL · KEL-U · KEL-ER Up to IP66 / UL 4X 1–35 mm (to 75 mm) 10/16/24-pin cut-outs
Membrane
Membrane Cable Entry Plates

For sealing a handful of individual cables with the fastest install — no frame, no grommets. Snap-in or screw-in as each cable passes straight through the membrane. (Routing many cables through one cut-out? Use a KEL frame.)

1.5–22 mm cable Ø Snap-in or screw-in Grommet-free
Brush seal
Cable Entry with Brush Seal

For routing high counts of unterminated cables that change often, where dust and particle reduction matters more than a full IP seal. Screw or snap fit to suit the panel. (Need a sealed rating? Use membrane plates or a KEL frame.)

Particle reduction Screw or snap fit High cable count
KVT series
Split Cable Glands

For sealing a single pre-terminated cable at an existing gland point without cutting the connector off. KVT split glands guide and re-route on a standard gland thread — the fastest retrofit.

Pre-terminated cables Standard gland thread Screw mount
Hygienic
Hygienic Cable Entries

For washdown, cleanroom and food/pharma environments that must pass a hygiene spec. FDA-compliant entries with smooth, visible surfaces and no dirt traps.

FDA-compliant Washdown / cleanroom Smooth surfaces
Strain relief & EMC
Strain Relief & EMC

For EMI shielding or dedicated strain relief on the same entry. EMC cable collectors with shielding plus strain-relief entries certified to EN 62444 — the specialist path when a standard entry won't pass the EMC spec.

EMI shielding EN 62444 Integrated strain relief
Split Cable Entry Frames

One cut-out. Every cable, sealed.

icotek's centrally split KEL frames take KT grommets sized to each cable, so a large number of cables — with connectors or without — route and seal through a single panel cut-out. The split design means you assemble around pre-terminated cables without cutting connectors off.

Quick to assemble for retrofits and maintenance, the frames match the cut-out dimensions of standard 10-, 16- and 24-pin industrial connectors and double as a strain relief on every cable — sealing up to IP66 / UL Type 4X on the KEL-ER series.

Centrally split design

Assemble around pre-terminated cables — no need to cut connectors off.

KT grommets per cable

Slit grommets sized to each cable diameter seal every entry individually.

Up to IP66 / UL Type 4X

The injected-seal KEL-ER series achieves IP66 with single grommets.

Integrated strain relief

Frames act as a strain relief on every cable, certified to EN 62444.

Standard connector cut-outs

Match 10-, 16- and 24-pin industrial connector openings for easy retrofit.

icotek

One system for every cable entry.

From split frames and grommets to glands, brush seals, hygienic and EMC entries — the complete icotek range is stocked across Australia through TROPAC. Talk to a PAC to match the right entry to your job, or browse the full range online.

Talk to a specialist

Need help specifying?

Send the team your application and a TROPAC Product Application Consultant will come back with the right icotek product, stock position and account pricing — usually same business day.

  • Selection & cross-reference from your current part numbers
  • Live stock check across QLD, NSW & VIC
  • Trade-account & project pricing
Enquiry · icotek
No obligation · usually same business day