{"product_id":"ups-control-module-24vdc-40a-1","title":"CP DC-UPS 24V 40A UPS Module","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller CP DC-UPS 24V 40A is the high-current model in the CP DC-UPS range, designed for 24VDC control systems with larger continuous loads. In normal operation the input voltage passes directly through to the load. On mains failure the system switches instantly to battery operation, keeping PLCs, sensors, and critical loads running without interruption. Three relay outputs and three active transistor outputs provide full remote monitoring and control via PLC or DCS. Compatible with Weidmüller CP A Battery modules from 3.4Ah to 17Ah, with buffer times selectable from 30 seconds to indefinite via front-panel rotary switch.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e40A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Current, max.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e48A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMax. Approved Input Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e52A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e20–30V DC (nom. 24V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e≥96% (charging) \/ ≥98% (charged or buffer mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eBattery Compatibility\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eLead-acid VRLA 3.4, 7.2, 12, 17Ah (CP A Battery series, max. 2 in parallel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eBuffer Times\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e0.5, 1, 3, 5, 10, 20, 30, 45 min, ∞ — selectable via rotary switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eBattery Availability Test\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eEvery minute (integrated charger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eRemote Monitoring\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e3× relay outputs + 3× active transistor outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eStatus Indication\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eGreen\/yellow LED: normal\/buffering — Yellow\/red LED: temperature alarm, switch-off, battery fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eControl Input\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eBattery interlock (remote disconnection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eScrew connection, 0.5–16mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eMetal, corrosion resistant, DIN-rail (TS35), IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eDimensions (H×W×D)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e130 × 66 × 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e−25°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMTBF\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e\u0026gt;500,000 h (IEC 61709 \/ SN29500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCertifications\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eCE, cULus (E258476), DNV-GL, TÜV Type Approved, RoHS Conform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCountry of Manufacture\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e1370040010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003e40A continuous output — the high-current model in the CP DC-UPS range; max. output 48A\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eInstant switchover to battery on mains failure — no interruption to connected loads\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003e3× relay outputs and 3× transistor outputs for full PLC\/DCS remote monitoring and control\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eBuffer times selectable from 30 seconds to indefinite; battery tested every minute by integrated charger\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eCompatible with CP A Battery modules: 3.4, 7.2, 12, 17Ah (max. 2 in parallel)\u003c\/li\u003e\n\u003cli\u003eMTBF \u0026gt;500,000 h — CE, cULus, DNV-GL, TÜV Type Approved, RoHS Conform. Made in Germany.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48202893099256,"sku":"1370040010","price":1091.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/1370040010_1.jpg?v=1776774690","url":"https:\/\/www.tropac.com.au\/products\/ups-control-module-24vdc-40a-1","provider":"TROPAC","version":"1.0","type":"link"}