{"product_id":"em220-rtu-4di2do-3-phase-energy-meter-with-modbus-rtu-4di-2do-1","title":"3-Phase Energy Meter with Modbus RTU, 4DI\/2DO","description":"\u003cp style=\"color:#111827;font-family:Arial,sans-serif;font-size:15px;line-height:1.6;margin:0 0 16px;\"\u003eThe EM220-RTU-4DI2DO is a panel-mount multifunction energy meter from Weidmüller's BasicLine range, designed for accurate power measurement in single-phase and three-phase installations. It connects to current transformers up to 5000 A primary and communicates measured values in real time via Modbus RTU over RS485 — making it well suited to switchboard builders, BMS integrators, and energy management applications where reliable sub-metering data is required. The built-in LCD display provides direct local readout of all key parameters without the need for an external tool or gateway.\u003c\/p\u003e\u003cfigure class=\"table\" style=\"margin-left:0;margin-right:auto;width:100%;\"\u003e\u003ctable style=\"border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eMeasurement Parameters\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eVoltage, current, active power, reactive power, apparent power, power factor, frequency, import\/export active and reactive energy, total system power demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eNetwork Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e1-phase 2-wire (L+N, L1+L2), 3-phase 3-wire (L1+L2+L3), 3-phase 4-wire (L1+L2+L3+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eVoltage Measurement Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e50–600 V AC (L-L) \/ 50–345 V AC (L-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eCurrent Input\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eCT secondary 1 A or 5 A — supports up to 5000 A primary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eVoltage 0.5% \/ Current 0.5% \/ Active energy Class 0.5S (IEC 62053-22), Class 0.5 (IEC 61557-12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eRS485 — Modbus RTU (parity: none\/even\/odd; stop bits: 1 or 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eDigital I\/O\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e4 digital inputs, 2 configurable digital outputs, pulse output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eLCD — all measured parameters accessible on-unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e75–270 V AC \/ 100–380 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e45–65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eFront panel IP51 \/ Rear IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eFront panel mount (DIN rail adapter available — EM220 BRACKET, 3068970000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e96 × 96 × 74 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e360 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e-25 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eScrew terminal — 0.5–2.5 mm² solid or stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eRoHS compliant (with exemption 7a, 7cI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"color:#111827;padding:6px 10px;\"\u003e7760051005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cul style=\"color:#374151;font-family:Arial,sans-serif;font-size:14px;line-height:1.6;margin:0 0 16px;padding-left:20px;\"\u003e\n\u003cli\u003eClass 0.5S active energy accuracy per IEC 62053-22 — suitable for utility-grade sub-metering and energy auditing applications\u003c\/li\u003e\n\u003cli\u003eCT connection supports primary currents up to 5000 A — no need for direct high-current wiring into the meter\u003c\/li\u003e\n\u003cli\u003eModbus RTU over RS485 enables direct integration with SCADA, BMS, and energy management systems\u003c\/li\u003e\n\u003cli\u003e4 digital inputs and 2 configurable digital outputs for alarm, pulse counting, and load control functions\u003c\/li\u003e\n\u003cli\u003e96 × 96 mm front-panel form factor with optional DIN rail bracket (EM220 BRACKET, 3068970000) for flexible installation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48960811532536,"sku":"7760051005","price":310.52,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/7760051005_1_95af0e14-99a6-4dc1-b5dd-35cc969c22d4.jpg?v=1781633008","url":"https:\/\/www.tropac.com.au\/products\/em220-rtu-4di2do-3-phase-energy-meter-with-modbus-rtu-4di-2do-1","provider":"TROPAC","version":"1.0","type":"link"}